From 3eec3af8daf8fcdf02857f43a7a768aebcf66d17 Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Fri, 23 Jan 2026 22:49:52 -0500 Subject: [PATCH 01/14] why does this not already exist? --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 16 +++++++++++++++- 1 file changed, 15 insertions(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index 5b427a58e7..60be413231 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -13,7 +13,7 @@ The terms specified below are defined for further use within the procedures. :* Permanent Brig/Permabrig/Brig: A secure location for the long-term confinement of Prisoners. Typically outfitted to sustain the basic survival needs of the Prisoners within. ==Right to Refuse Service== -All crew operating within their designated job locations are given the right to refuse service at any time for disorderly or abusive conduct. Additionally, all crew members are permitted to use nonlethal force to remove noncompliant or disorderly individuals only when such persons pose a threat to the safety of staff members, or disrupt the orderly functioning of the station. Service may not be refused to first responders acting to address or mitigate an emergency or crisis situation, unless such conduct is egregiously disorderly or abusive. +All crew operating within their designated job locations are given the right to refuse service at any time for disorderly or abusive conduct. Additionally, all crew members are permitted to use nonlethal force to remove noncompliant or disorderly individuals only when such persons pose a threat to the safety of staff members, or disrupt the orderly functioning of the station. Service may not be refused to first responders or damage control personnel acting to address or mitigate an emergency or crisis situation, unless such conduct is egregiously disorderly or abusive. = Entity Definitions = The following definitions are provided to clarify the legal protections- and obligations- that Standard Operating Procedures and Space Law provide to any given entity. Unless explicitly covered by a more distinctive term, all Entities are to be treated as such until clarification is provided. @@ -79,6 +79,7 @@ Controlled Items include any item that is restricted from general possession and * Technology utilizing bluespace as an integral part of its function. * Teleportation and portal technology. * Hydraulic or powered equipment designed for the electronic or mechanical bypass of secure-access systems. +* Rapid construction/piping technology Any individual requiring any above item in the course of their job, or for regular function, may request a document of authorization from the relevant departmental head. Such a document must have an itemized list of the approved Controlled Items, the name and position of the holder, and a signed and stamped statement by the authorizing party. @@ -375,3 +376,16 @@ Medical staff are afforded the right to quarantine individuals that currently su ==Foreign Bodies== Any parasitic alien organism that requires a living host to live and reproduce must be eliminated. An exception can be made for experimental purposes, provided a CO, CMO and Mystagogue were to approve it. + +=Engineering Regulations= +==Building Permits== +Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenence tunnels are considered abandoned and do not require permission to modify. + +==Emergency Access== +In an emergency situation, engineers are permitted to hack doors to gain unauthorized access to locations if said locations require urgent repairs. + +==Hazard Zones== +An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To protect crew lives, engineers must demarcate hazard zones with holofans, inflatable walls, or engineering tape prior to beginning work. Civilians shall evaccuate from and avoid hazard zones. Willfully contributing to the spread of a hazard zone by ignoring firelocks and/or engineering tape shall render an Employee liable to charges of endangerment. + +==Condemned Areas== +The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. Doors leading to such areas shall be welded or bolted to prevent crew access. \ No newline at end of file From d677ec9cbec83419db7c13e8b197e2db40c99b8f Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Fri, 23 Jan 2026 22:52:48 -0500 Subject: [PATCH 02/14] english is a silly little language --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index 60be413231..487d56d33c 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -379,7 +379,7 @@ Any parasitic alien organism that requires a living host to live and reproduce m =Engineering Regulations= ==Building Permits== -Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenence tunnels are considered abandoned and do not require permission to modify. +Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. ==Emergency Access== In an emergency situation, engineers are permitted to hack doors to gain unauthorized access to locations if said locations require urgent repairs. From 1d95551bc09fd79349073426254df9ec9efe0493 Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Fri, 23 Jan 2026 22:55:01 -0500 Subject: [PATCH 03/14] epic autocorrect ops --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index 487d56d33c..c919167168 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -385,7 +385,7 @@ Any additions or modifications to the station's structural layout, power network In an emergency situation, engineers are permitted to hack doors to gain unauthorized access to locations if said locations require urgent repairs. ==Hazard Zones== -An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To protect crew lives, engineers must demarcate hazard zones with holofans, inflatable walls, or engineering tape prior to beginning work. Civilians shall evaccuate from and avoid hazard zones. Willfully contributing to the spread of a hazard zone by ignoring firelocks and/or engineering tape shall render an Employee liable to charges of endangerment. +An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To protect crew lives, engineers must demarcate hazard zones with holofans, inflatable walls, or engineering tape prior to beginning work. Civilians shall evacuate from and avoid hazard zones. Willfully contributing to the spread of a hazard zone by ignoring firelocks and/or engineering tape shall render an Employee liable to charges of endangerment. ==Condemned Areas== The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. Doors leading to such areas shall be welded or bolted to prevent crew access. \ No newline at end of file From a0fb085f12cd46acb5f2a12ec4e307f6a10136e1 Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 24 Jan 2026 14:17:20 -0500 Subject: [PATCH 04/14] health and safety regs --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index c919167168..29ad7169d4 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -378,6 +378,12 @@ Medical staff are afforded the right to quarantine individuals that currently su Any parasitic alien organism that requires a living host to live and reproduce must be eliminated. An exception can be made for experimental purposes, provided a CO, CMO and Mystagogue were to approve it. =Engineering Regulations= +==Health & Safety== +* In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. +* The atmospheric distribution pipe ("distro") shall be maintained between 100kPa-300kPa, at a ratio of 70-80% nitrogen, 20-30% oxygen. +* The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. +* Burn chambers may not be constructed within the station or directly adjacent to the station's hull. + ==Building Permits== Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. From 9676f392985648ed69968192896e662be53b195a Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 24 Jan 2026 14:19:14 -0500 Subject: [PATCH 05/14] epic whitespace ops --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index 29ad7169d4..df66359cef 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -385,7 +385,7 @@ Any parasitic alien organism that requires a living host to live and reproduce m * Burn chambers may not be constructed within the station or directly adjacent to the station's hull. ==Building Permits== -Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. +Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. ==Emergency Access== In an emergency situation, engineers are permitted to hack doors to gain unauthorized access to locations if said locations require urgent repairs. From 459131b4909fa93cb7d07f9bb8760ab2df560ce8 Mon Sep 17 00:00:00 2001 From: "pre-commit-ci[bot]" <66853113+pre-commit-ci[bot]@users.noreply.github.com> Date: Sun, 25 Jan 2026 03:32:23 +0000 Subject: [PATCH 06/14] [pre-commit.ci] auto fixes from pre-commit.com hooks for more information, see https://pre-commit.ci --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index df66359cef..525a2b0b5e 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -394,4 +394,4 @@ In an emergency situation, engineers are permitted to hack doors to gain unautho An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To protect crew lives, engineers must demarcate hazard zones with holofans, inflatable walls, or engineering tape prior to beginning work. Civilians shall evacuate from and avoid hazard zones. Willfully contributing to the spread of a hazard zone by ignoring firelocks and/or engineering tape shall render an Employee liable to charges of endangerment. ==Condemned Areas== -The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. Doors leading to such areas shall be welded or bolted to prevent crew access. \ No newline at end of file +The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. Doors leading to such areas shall be welded or bolted to prevent crew access. From b82048e0975a9906a5684a37723e64514957107f Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 24 Jan 2026 22:48:15 -0500 Subject: [PATCH 07/14] the hell is a gar-TEG? --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index 525a2b0b5e..b318862991 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -382,7 +382,7 @@ Any parasitic alien organism that requires a living host to live and reproduce m * In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. * The atmospheric distribution pipe ("distro") shall be maintained between 100kPa-300kPa, at a ratio of 70-80% nitrogen, 20-30% oxygen. * The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. -* Burn chambers may not be constructed within the station or directly adjacent to the station's hull. +* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless recieving written authorization from the Central Command Bureau of Engineering Standards. ==Building Permits== Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. From 3b170a396f8141e4e8b9fd0206502741a646e82b Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 24 Jan 2026 22:49:29 -0500 Subject: [PATCH 08/14] I hate English --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index b318862991..89f245b3ba 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -382,7 +382,7 @@ Any parasitic alien organism that requires a living host to live and reproduce m * In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. * The atmospheric distribution pipe ("distro") shall be maintained between 100kPa-300kPa, at a ratio of 70-80% nitrogen, 20-30% oxygen. * The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. -* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless recieving written authorization from the Central Command Bureau of Engineering Standards. +* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from the Central Command Bureau of Engineering Standards. ==Building Permits== Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. From e83764422ab4b8bfd268c682810c9a4ecb8abb9f Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Tue, 27 Jan 2026 13:54:50 -0500 Subject: [PATCH 09/14] Apply suggestions from code review Co-authored-by: Vanessa <908648+ShepardToTheStars@users.noreply.github.com> Signed-off-by: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 14 +++++++------- 1 file changed, 7 insertions(+), 7 deletions(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index 89f245b3ba..ba4deec269 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -13,7 +13,7 @@ The terms specified below are defined for further use within the procedures. :* Permanent Brig/Permabrig/Brig: A secure location for the long-term confinement of Prisoners. Typically outfitted to sustain the basic survival needs of the Prisoners within. ==Right to Refuse Service== -All crew operating within their designated job locations are given the right to refuse service at any time for disorderly or abusive conduct. Additionally, all crew members are permitted to use nonlethal force to remove noncompliant or disorderly individuals only when such persons pose a threat to the safety of staff members, or disrupt the orderly functioning of the station. Service may not be refused to first responders or damage control personnel acting to address or mitigate an emergency or crisis situation, unless such conduct is egregiously disorderly or abusive. +All crew operating within their designated job locations are given the right to refuse service at any time for disorderly or abusive conduct. Additionally, all crew members are permitted to use nonlethal force to remove noncompliant or disorderly individuals only when such persons pose a threat to the safety of staff members, or disrupt the orderly functioning of the station. Service may not be refused to first responders or damage-control personnel acting to address or mitigate an emergency or crisis situation, unless such conduct is egregiously disorderly or abusive. = Entity Definitions = The following definitions are provided to clarify the legal protections- and obligations- that Standard Operating Procedures and Space Law provide to any given entity. Unless explicitly covered by a more distinctive term, all Entities are to be treated as such until clarification is provided. @@ -380,18 +380,18 @@ Any parasitic alien organism that requires a living host to live and reproduce m =Engineering Regulations= ==Health & Safety== * In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. -* The atmospheric distribution pipe ("distro") shall be maintained between 100kPa-300kPa, at a ratio of 70-80% nitrogen, 20-30% oxygen. +* The atmospheric distribution pipe ("distro") pressure should be no more than 500 kPa and composition should be a ratio of 70-80% nitrogen and 20-30% oxygen. * The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. -* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from the Central Command Bureau of Engineering Standards. +* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from Central Command. ==Building Permits== -Any additions or modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved by the CO or Chief Engineer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels are considered abandoned and do not require permission to modify. +Any renovations larger than small modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved expressly by the Chief Engineer, or if a Chief Engineer is not present, the Captain or Acting Commanding Officer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels do not require permission to modify. However, any modifications to maintenance tunnel passageways should ensure they remain traversable and unobstructed by personnel who need to use them as part of their job. ==Emergency Access== -In an emergency situation, engineers are permitted to hack doors to gain unauthorized access to locations if said locations require urgent repairs. +In an emergency situations, engineers are permitted to bypass door access (i.e. hack) and gain access to unauthorized locations if said locations require repairs. ==Hazard Zones== -An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To protect crew lives, engineers must demarcate hazard zones with holofans, inflatable walls, or engineering tape prior to beginning work. Civilians shall evacuate from and avoid hazard zones. Willfully contributing to the spread of a hazard zone by ignoring firelocks and/or engineering tape shall render an Employee liable to charges of endangerment. +An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To ensure crew safety, engineering personnel are required to demarcate hazard zones with holofans, inflatable walls, and/or engineering tape prior to beginning work. Any non-authorized personnel impeding or preventing repairs in hazardous areas may be liable for endangerment. ==Condemned Areas== -The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. Doors leading to such areas shall be welded or bolted to prevent crew access. +The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. In the event that there is no Chief Engineer, any engineer may condemn a section of the station with authorization from the Captain or Acting Commanding Officer. Doors leading to such areas shall be welded or bolted to prevent crew access. From 318834107bc7ca5f8f17d680d4377333beeb5a9d Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Tue, 27 Jan 2026 13:56:55 -0500 Subject: [PATCH 10/14] epic grammar ops --- .wiki/_DV/Laws/StandardOperatingProcedure.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/.wiki/_DV/Laws/StandardOperatingProcedure.txt b/.wiki/_DV/Laws/StandardOperatingProcedure.txt index ba4deec269..0847097712 100644 --- a/.wiki/_DV/Laws/StandardOperatingProcedure.txt +++ b/.wiki/_DV/Laws/StandardOperatingProcedure.txt @@ -388,7 +388,7 @@ Any parasitic alien organism that requires a living host to live and reproduce m Any renovations larger than small modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved expressly by the Chief Engineer, or if a Chief Engineer is not present, the Captain or Acting Commanding Officer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels do not require permission to modify. However, any modifications to maintenance tunnel passageways should ensure they remain traversable and unobstructed by personnel who need to use them as part of their job. ==Emergency Access== -In an emergency situations, engineers are permitted to bypass door access (i.e. hack) and gain access to unauthorized locations if said locations require repairs. +In emergency situations, engineers are permitted to bypass door access (i.e. hack) and gain access to unauthorized locations if said locations require repairs. ==Hazard Zones== An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To ensure crew safety, engineering personnel are required to demarcate hazard zones with holofans, inflatable walls, and/or engineering tape prior to beginning work. Any non-authorized personnel impeding or preventing repairs in hazardous areas may be liable for endangerment. From 5fbb95ce4b329b8e2b513096382c689d0b717ad1 Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 31 Jan 2026 15:11:14 -0500 Subject: [PATCH 11/14] epic guidebook ops --- .../Guidebook/StandardOperatingProcedure.yml | 43 +++++++++++++++++++ .../BuildingPermits.xml | 5 +++ .../EngineeringRegulations/CondemnedAreas.xml | 5 +++ .../EmergencyAccess.xml | 5 +++ .../EngineeringRegulations.xml | 18 ++++++++ .../EngineeringRegulations/HazardZones.xml | 5 +++ .../HealthAndSafety.xml | 8 ++++ 7 files changed, 89 insertions(+) create mode 100644 Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/BuildingPermits.xml create mode 100644 Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/CondemnedAreas.xml create mode 100644 Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EmergencyAccess.xml create mode 100644 Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml create mode 100644 Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HazardZones.xml create mode 100644 Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml diff --git a/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml b/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml index 7c0716921b..98980d5a9d 100644 --- a/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml +++ b/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml @@ -12,6 +12,7 @@ - SecurityandJusticeRegulations - Hearings - MedicalRegulations + - EngineeringRegulations # General Regulations Main Directory @@ -104,6 +105,19 @@ - Quarantine - StandardOfCare +# Engineering Regulations Main Directory +- type: guideEntry + id: EngineeringRegulationsRegulations + name: Engineering Regulations + text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml + priority: 1 + children: + - HealthAndSafety + - BuildingPermits + - EmergencyAccess + - HazardZones + - CondemnedAreas + ## General Regulations Entries - type: guideEntry id: Definitions @@ -298,3 +312,32 @@ id: StandardOfCare name: Standard Of Care text: /ServerInfo/Guidebook/_DV/SpaceLaw/MedicalRegulations/StandardOfCare.xml + + ## Engineering Regulations Entries +- type: guideEntry + id: HealthAndSafety + name: Health and Safety + text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml + + +- type: guideEntry + id: BuildingPermits + name: Building Permits + text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/BuildingPermits.xml + + +- type: guideEntry + id: EmergencyAccess + name: Emergency Access + text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EmergencyAccess.xml + + +- type: guideEntry + id: HazardZones + name: Hazard Zones + text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HazardZones.xml + +- type: guideEntry + id: CondemnedAreas + name: CondemnedAreas + text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/CondemnedAreas.xml diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/BuildingPermits.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/BuildingPermits.xml new file mode 100644 index 0000000000..ca1625f6ac --- /dev/null +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/BuildingPermits.xml @@ -0,0 +1,5 @@ + + # Building Permits +Any renovations larger than small modifications to the station's structural layout, power network, or atmospheric system shall require a building permit or work order approved expressly by the Chief Engineer, or if a Chief Engineer is not present, the Captain or Acting Commanding Officer. Modifications within departments shall additionally require the approval of the relevant department head. Areas within maintenance tunnels do not require permission to modify. However, any modifications to maintenance tunnel passageways should ensure they remain traversable and unobstructed by personnel who need to use them as part of their job. + + diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/CondemnedAreas.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/CondemnedAreas.xml new file mode 100644 index 0000000000..9a58d715dd --- /dev/null +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/CondemnedAreas.xml @@ -0,0 +1,5 @@ + + # Condemned Areas +The Chief Engineer may declare a section of the station condemned if repairs cannot be reasonably completed. In the event that there is no Chief Engineer, any engineer may condemn a section of the station with authorization from the Captain or Acting Commanding Officer. Doors leading to such areas shall be welded or bolted to prevent crew access. + + diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EmergencyAccess.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EmergencyAccess.xml new file mode 100644 index 0000000000..87cf6136a6 --- /dev/null +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EmergencyAccess.xml @@ -0,0 +1,5 @@ + + # Emergency Access +In emergency situations, engineers are permitted to bypass door access (i.e. hack) and gain access to unauthorized locations if said locations require repairs. + + diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml new file mode 100644 index 0000000000..14f88ab9cb --- /dev/null +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml @@ -0,0 +1,18 @@ + + +# Engineering Regulations + +Engineering Regulations are the best practices, safety regulations, and department policies Engineering personnel must follow. + +[textlink="Health and Safety" link="HealthAndSafety"] regulations define standards for wiring, piping, and burn chambers. + +[textlink="Building Permits" link="BuildingPermits"] may be issued by the Chief Engineer to permit stationside construction or modifications. + +In emergency situations, Engineering personnel may gain [textlink="Emergency Access" link="EmergencyAccess"] to unauthorized locations if said locations require urgent repairs. + +[textlink="Hazard Zones" link="HazardZones"] must be clearly marked by Engineering personnel. + +[textlink="Condemned Areas" link="CondemnedAreas"] are declared by the Chief Engineer if repairs cannot be reasonably completed. + + + diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HazardZones.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HazardZones.xml new file mode 100644 index 0000000000..c60029825e --- /dev/null +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HazardZones.xml @@ -0,0 +1,5 @@ + + # Hazard Zones +An area with a hull breach, hazardous material leak, or other similar danger shall be considered a hazard zone. To ensure crew safety, engineering personnel are required to demarcate hazard zones with holofans, inflatable walls, and/or engineering tape prior to beginning work. Any non-authorized personnel impeding or preventing repairs in hazardous areas may be liable for endangerment. + + diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml new file mode 100644 index 0000000000..635ea98900 --- /dev/null +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml @@ -0,0 +1,8 @@ + + # Health and Safety +* In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. +* The atmospheric distribution pipe ("distro") pressure should be no more than 500 kPa and composition should be a ratio of 70-80% nitrogen and 20-30% oxygen. +* The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. +* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from Central Command. + + From f348908c4e3f1b761feab32bd5cc7319317d84b2 Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 31 Jan 2026 15:19:20 -0500 Subject: [PATCH 12/14] fix EngieeringRegulations type --- .../Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml b/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml index 98980d5a9d..9d74e0bf3f 100644 --- a/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml +++ b/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml @@ -107,7 +107,7 @@ # Engineering Regulations Main Directory - type: guideEntry - id: EngineeringRegulationsRegulations + id: EngineeringRegulations name: Engineering Regulations text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml priority: 1 From 96390c7d09dd54e9901bac2fe1becf33e1264166 Mon Sep 17 00:00:00 2001 From: zelezniciar1 <39102800+zelezniciar1@users.noreply.github.com> Date: Sat, 31 Jan 2026 15:31:26 -0500 Subject: [PATCH 13/14] minor fixes --- .../_DV/Guidebook/StandardOperatingProcedure.yml | 2 +- .../_DV/SpaceLaw/ControlledISA/ControlledItems.xml | 1 + .../EngineeringRegulations/EngineeringRegulations.xml | 2 +- .../EngineeringRegulations/HealthAndSafety.xml | 11 +++++++---- .../GeneralRegulations/RightsToRefuseService.xml | 2 +- 5 files changed, 11 insertions(+), 7 deletions(-) diff --git a/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml b/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml index 9d74e0bf3f..04a1b6e939 100644 --- a/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml +++ b/Resources/Prototypes/_DV/Guidebook/StandardOperatingProcedure.yml @@ -339,5 +339,5 @@ - type: guideEntry id: CondemnedAreas - name: CondemnedAreas + name: Condemned Areas text: /ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/CondemnedAreas.xml diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/ControlledISA/ControlledItems.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/ControlledISA/ControlledItems.xml index a3838d9a94..1058bfe24d 100644 --- a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/ControlledISA/ControlledItems.xml +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/ControlledISA/ControlledItems.xml @@ -16,6 +16,7 @@ - Technology utilizing bluespace as an integral part of its function. - Teleportation and portal technology. - Hydraulic or powered equipment designed for the electronic or mechanical bypass of secure-access systems. + - Rapid construction/piping technology Any individual requiring any above item in the course of their job, or for regular function, may request a document of authorization from the relevant departmental head. Such a document must have an itemized list of the approved Controlled Items, the name and position of the holder, and a signed and stamped statement by the authorizing party. diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml index 14f88ab9cb..d0211885b2 100644 --- a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/EngineeringRegulations.xml @@ -8,7 +8,7 @@ Engineering Regulations are the best practices, safety regulations, and departme [textlink="Building Permits" link="BuildingPermits"] may be issued by the Chief Engineer to permit stationside construction or modifications. -In emergency situations, Engineering personnel may gain [textlink="Emergency Access" link="EmergencyAccess"] to unauthorized locations if said locations require urgent repairs. +[textlink="Emergency Access" link="EmergencyAccess"] states that in emergency situations, Engineering personnel may gain unauthorized access to locations if said locations require urgent repairs. [textlink="Hazard Zones" link="HazardZones"] must be clearly marked by Engineering personnel. diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml index 635ea98900..b33b634c98 100644 --- a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml @@ -1,8 +1,11 @@ # Health and Safety -* In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. -* The atmospheric distribution pipe ("distro") pressure should be no more than 500 kPa and composition should be a ratio of 70-80% nitrogen and 20-30% oxygen. -* The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. -* Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from Central Command. + - In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. + + - The atmospheric distribution pipe ("distro") pressure should be no more than 500 kPa and composition should be a ratio of 70-80% nitrogen and 20-30% oxygen. + + - The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. + + - Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from Central Command. diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/GeneralRegulations/RightsToRefuseService.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/GeneralRegulations/RightsToRefuseService.xml index 72560559ce..d7cc23b1cb 100644 --- a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/GeneralRegulations/RightsToRefuseService.xml +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/GeneralRegulations/RightsToRefuseService.xml @@ -1,5 +1,5 @@ # Right to Refuse Service - All crew operating within their designated job locations are given the right to refuse service at any time for disorderly or abusive conduct. Additionally, all crew members are permitted to use nonlethal force to remove noncompliant or disorderly individuals only when such persons pose a threat to the safety of staff members, or disrupt the orderly functioning of the station. Service may not be refused to first responders acting to address or mitigate an emergency or crisis situation, unless such conduct is egregiously disorderly or abusive. + All crew operating within their designated job locations are given the right to refuse service at any time for disorderly or abusive conduct. Additionally, all crew members are permitted to use nonlethal force to remove noncompliant or disorderly individuals only when such persons pose a threat to the safety of staff members, or disrupt the orderly functioning of the station. Service may not be refused to first responders or damage-control personnel acting to address or mitigate an emergency or crisis situation, unless such conduct is egregiously disorderly or abusive. From 6eb9eb5d1e5d95f6cba138977f690f904aa4c282 Mon Sep 17 00:00:00 2001 From: "pre-commit-ci[bot]" <66853113+pre-commit-ci[bot]@users.noreply.github.com> Date: Sat, 31 Jan 2026 20:34:19 +0000 Subject: [PATCH 14/14] [pre-commit.ci] auto fixes from pre-commit.com hooks for more information, see https://pre-commit.ci --- .../_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml index b33b634c98..5184f0ba66 100644 --- a/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml +++ b/Resources/ServerInfo/Guidebook/_DV/SpaceLaw/EngineeringRegulations/HealthAndSafety.xml @@ -1,11 +1,11 @@ # Health and Safety - In public areas, all wiring must be concealed under tiles. In non-public areas, catwalks are recommended to be placed for the safety and mobility of workers. - + - The atmospheric distribution pipe ("distro") pressure should be no more than 500 kPa and composition should be a ratio of 70-80% nitrogen and 20-30% oxygen. - + - The atmospheric waste pipe ("waste") shall be kept free of clogging, and directed either to recycling, gas storage, or space. - + - Newly constructed burn chambers may not be located within the station or directly adjacent to the station's hull, unless receiving written authorization from Central Command.