mirror of
https://github.com/DeltaV-Station/Delta-v.git
synced 2026-10-03 01:27:26 +00:00
Add door electronics access configuration menu (#17778)
* Add door electronics configuration menu
* Use file-scoped namespaces
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Open door electronics configuration menu only with network configurator
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Make the access list in the id card computer a separate control
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Fix merge conflict
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove DoorElectronics tag
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Integrate doors with #17927
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Move door electornics ui stuff to the right place
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Some review fixes
Signed-off-by: c4llv07e <kseandi@gmail.com>
* More fixes
Signed-off-by: c4llv07e <kseandi@gmail.com>
* review fix
Signed-off-by: c4llv07e <kseandi@gmail.com>
* move all accesses from airlock prototypes to door electronics
Signed-off-by: c4llv07e <kseandi@gmail.com>
* rework door electronics config access list
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove Linq from the door electronics user interface
* [WIP] Add EntityWhitelist to the activatable ui component
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Better interaction system
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Refactor
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Fix some door electronics not working without AccessReaderComponent
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Move AccessReaderComponent update code to the AccessReaderSystem
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unnecesary newlines in the door access prototypes
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unused variables in access level control
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unnecessary method from the door electronics configuration menu
Signed-off-by: c4llv07e <kseandi@gmail.com>
* [WIP] change access type from string to ProtoId<AccessLevelPrototype>
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Remove unused methods
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Newline fix
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Restored to a functional state
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Fix access configurator not working with door electronics AccessReaderComponent
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Replace all string access fields with ProtoId
Signed-off-by: c4llv07e <kseandi@gmail.com>
* move access level control initialization into Populate method
Signed-off-by: c4llv07e <kseandi@gmail.com>
* Review
---------
Signed-off-by: c4llv07e <kseandi@gmail.com>
Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
(cherry picked from commit 64bb8dbdd5)
This commit is contained in:
co-authored by
metalgearsloth
parent
516e5c6081
commit
ecbef2b8eb
@@ -35,6 +35,7 @@ using Robust.Shared.Map.Components;
|
||||
using Robust.Shared.Physics;
|
||||
using Robust.Shared.Physics.Components;
|
||||
using Robust.Shared.Player;
|
||||
using Robust.Shared.Prototypes;
|
||||
using Robust.Shared.Utility;
|
||||
|
||||
namespace Content.Server.Administration.Systems;
|
||||
@@ -844,14 +845,14 @@ public sealed partial class AdminVerbSystem
|
||||
{
|
||||
var allAccess = _prototypeManager
|
||||
.EnumeratePrototypes<AccessLevelPrototype>()
|
||||
.Select(p => p.ID).ToArray();
|
||||
.Select(p => new ProtoId<AccessLevelPrototype>(p.ID)).ToArray();
|
||||
|
||||
_accessSystem.TrySetTags(entity, allAccess);
|
||||
}
|
||||
|
||||
private void RevokeAllAccess(EntityUid entity)
|
||||
{
|
||||
_accessSystem.TrySetTags(entity, Array.Empty<string>());
|
||||
_accessSystem.TrySetTags(entity, new List<ProtoId<AccessLevelPrototype>>());
|
||||
}
|
||||
|
||||
public enum TricksVerbPriorities
|
||||
|
||||
Reference in New Issue
Block a user